Weekly Maintenance Check Report |
Date Check Completed | 2021-10-17 |
Vessel Name | Brahminy Kite |
BE3004 Navigation Lights and Panel |
Test Navigation Lights |
|
Test dimmer function for navigation light panel |
|
FF1002/FF1004 Port and Starboard fire pumps |
Check Pumps are secure |
|
Operate pump checking for noise and vibration |
|
Check for leaking seals |
|
Restore valves to correct positions when finished |
|
HL1008 Passenger Areas |
Check Windows and frames |
|
Water Stains on Carpet |
|
Check locks, hinges, and closers on doors |
|
Check seats |
|
Check all furniture and fixtures for operation and damage |
|
Check all toilets for cleanliness |
|
SW1002/SW1004 port and starboard sea water strainers |
Open Strainers and Inspect |
|
Remove all debris from strainers |
|
Inspect interior of strainer box and gauze for corrosion and damage |
|
WT1002 Watertight doors and hatches |
Open each weaher/watertight/hatch and inspect seals |
|
All seals are soft and in good condition |
|
check all gaps within the seal |
|
Operate all closing dogs and lubricate as necessary |
|
EL4006 Emergency Lighting |
Check all emergency lights are fully operational using test switch if applicable |
|
FF1006/FF1008 Port and Startboard Fire Hydrant Pump |
Test run pumps to ensure remote starter is functioning |
|
Note discharge from fire hose to ensure enough output |
|
All valves operational |
|
FF2002 Fire Hydrants and Hoses |
Check the fire box, flaked hose and nozzel |
|
Fire hose in current test |
|
Check that valves are greased and operational |
|
check signage in good condition |
|
RB1002 Rescue Boat |
Start outboard engine |
|
Check fuel rank fittings and fuel hose |
|
Check fuel Tanks |
|
Check boat securing devices |
|
Check davit winches and pulleys are operating freely |
|
Check test and tag for lifing equippment |
|
EL3002 Air conditioner |
Clean casing and grill with vacuum cleaner brush |
|
Clean air filter behind air intake, vacuum off dust |
|
Ensure that each unit is cooling as required |
|
Check that each condenser unit is securely mounted and not making any undue noise |
|
Comments |
Stbd fire pump loose on mounting bolts , tightened up, will monitor, checked port side bolts on pump and also bit loose, may need threadlocker , willl monitor, fir main pump has hole in pipe near manifold, leaks saltwater into engine room when run,, female toilet sink drain blocked, removed plug and cleaned out, secondary strainer on genset very dirty, with mud silt, cleaned out and anode needs replacing, spoke with maintenance. Was unable to check or clean Genset primary as there is no gas detector on board, spoke with maintenance, they will do it when Genset is serviced which is due |
Completed |
YesNo |
Authorised by | N Raphael |