Weekly Maintenance Check Report |
Date Check Completed | 2024-10-20 |
Vessel Name | Brahminy Kite |
BE3004 Navigation Lights and Panel |
Test Navigation Lights |
|
Test dimmer function for navigation light panel |
|
FF1002/FF1004 Port and Starboard fire pumps |
Check Pumps are secure |
|
Operate pump checking for noise and vibration |
|
Check for leaking seals |
|
Restore valves to correct positions when finished |
|
HL1008 Passenger Areas |
Check Windows and frames |
|
Water Stains on Carpet |
|
Check locks, hinges, and closers on doors |
|
Check seats |
|
Check all furniture and fixtures for operation and damage |
|
Check all toilets for cleanliness |
|
SW1002/SW1004 port and starboard sea water strainers |
Open Strainers and Inspect |
|
Remove all debris from strainers |
|
Inspect interior of strainer box and gauze for corrosion and damage |
|
WT1002 Watertight doors and hatches |
Open each weaher/watertight/hatch and inspect seals |
|
All seals are soft and in good condition |
|
check all gaps within the seal |
|
Operate all closing dogs and lubricate as necessary |
|
EL4006 Emergency Lighting |
Check all emergency lights are fully operational using test switch if applicable |
|
FF1006/FF1008 Port and Startboard Fire Hydrant Pump |
Test run pumps to ensure remote starter is functioning |
|
Note discharge from fire hose to ensure enough output |
|
All valves operational |
|
FF2002 Fire Hydrants and Hoses |
Check the fire box, flaked hose and nozzel |
|
Fire hose in current test |
|
Check that valves are greased and operational |
|
check signage in good condition |
|
RB1002 Rescue Boat |
Start outboard engine |
|
Check fuel rank fittings and fuel hose |
|
Check fuel Tanks |
|
Check boat securing devices |
|
Check davit winches and pulleys are operating freely |
|
Check test and tag for lifing equippment |
|
EL3002 Air conditioner |
Clean casing and grill with vacuum cleaner brush |
|
Clean air filter behind air intake, vacuum off dust |
|
Ensure that each unit is cooling as required |
|
Check that each condenser unit is securely mounted and not making any undue noise |
|
Comments |
Genset primary and secondary strainer cleaned , secondary strainer had only couple barnacles this week, whereas last week had a coffee cup full or more , port mid void bilge alarm and pump tested, port mid void and port fwd void removed salt crust from bilges , vessel scrubbed with Truckwash from roof down , mats in vessel degreased and scrubbed clean , when inspecting fire / bilge strainers both were found dry, primed with salt water and secured lid , |
Completed |
YesNo |
Authorised by | N Raphael |